Vortex Flow Meter-Flow Measurement-Steam Mass Flow Meter-Flow Indicator-Flow Sensor-Flow Transmitter

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hebei

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-02 08:26

  • Browse the number:

    129

Send an inquiries

Company Profile

Hebei Xukang Meter Manufacturing Co., Ltd.

By certification [File Integrity]

Contact:Ms. Jenny Zhao(Mr.)  

Email:

Telephone:

Phone:

Area:Hebei

Address:Hebei

Website: http://u-ideal.jhhtqp.com/

Product details
Damp proof and anti-interference steam flowmeter

Technique parameter
Physical parameter
Nominal diameter: LUGB-A filled vortex flow meter Φ 10-Φ 500
LUGB-B plug-in type vortex flow meterΦ 200-Φ 2000
Measuring fluid: Liquid, gas, saturated vapor, super-heated steam
Standard condition: P=0.101325MPa T=20º C
Suitable environment temperature: -20º C~+55º C
Atmospheric pressure: 86KPa~106KPa
Relative humidity: 5%~95%
Fluid temperature: For filled vortex flow meter: -40~+42º C; For plug-in vortex flow meter: -40~+250º C
Pressure class: PN 1.0MPa, PN1.6MPa, PN2.5MPa, PN4.0MPa
LUGB A clamp-on vortex flow meter's flanges pressure are all PN2.5MPa, and their direct flange-connecting are PN1.0MPa pressure flange.
And LUGB-B plug vortex flow meter's flanges are all PN1.6Mpa bearing pressure as normal when out of factory. So if the needed pressure is larger than the stated pressure, advanced notification is necessary.
Accuracy class: LUGB-A 1class, 1.5class (0.5class and 0.2class can be negotiation)
LUGB B 2.5class (1.5class and 1.0class can be negotiation)
Vortex flow meter's largest measuring range refer to table 2, table 3, table 4, table 5, table 6 and table 7.
Digit intelligent vortex flow meter's measuring range: Liquid (0.30m/s~8.0m/s), gas, steam(2.8m/s~6.5m/s)
Anticorrosion class: Exia IICT4 explosion-proof type and ExdIICT5 flame-proof type.
Protection class: IP54, IP65
Body material: 1Cr18Ni9Ti(if other material is required, negotiation firstly)

3.2 electric factors
Working voltage: 12VDC, 24VDC, 3.6VDC Lithium battery (battery life is more that 2years. Only for field display)
Output signal
Voltage pulse of working condition instantaneous flow rate(low level≤ 1V, high level≥ 6V, pulse width10uS)
Voltage pulse for instantaneous flow rate on standard condition (limits to temperature and pressure integrative compensation type vortex flow meter. Low level≤ 1V, high level≥ 6V)
Working condition instantaneous flow rate is corresponding to 2-wire 4~20mA output (limit to temperature and pressure compensation integration type vortex flow meter, 3-wire system 4~20mA output)
Standard instantaneous flow rate is corresponding to 3-wire 4~20mA output (limited to temperature and pressure compensation type)
Communication type: RS232, RS485 or HART protocol (these protocol should be negotiated)
Indicating type
Field double rows liquid crystal digit display, can display both instant flow rate and total flow at the same time. For the temperature and pressure compensation type the indicator can display temperature, pressure, instantaneous flow rate and total flow in a cycle. (That is suitable to temperature and pressure compensation type or ordinary display type).
3-row field liquid crystal display: Can display flow rate and total flow at standard condition or temperature, pressure, density, flow rate, total flow, frequency and cell voltage at working condition.

Medium to be measured

≥85%,
Liquid\Gas\Steam(Single medium or medium can be viewed as single medium),Saturated steam with degree of dryness no less than 85 percent can be viewed as single medium

Temperature of Medium
(Flange Fasten Type) -40ºC~+250ºC\300ºC\400ºC\450ºC
(Inside Type) -20ºC~+250ºC\300ºC\400ºC

Pressure of Medium
1.6MPa 2.5MPa 4.0MPa (4.0MPa)

Accuracy
(Flange Fasten Type) ±0.5%\±1.0%\±1.5%\
(Inside Type) ±2.5%\
Rangeability 8:1 10:1 15:1 20:1

Rangeof FlowSpeed
(Liquid)0.3~7.0m/s\(Gas)4.0~60.0m/s
(Steam)5.0~70.0m/s

Specifications

Flange Fasten Type
Φ40\Φ50\Φ80\Φ100\Φ150
Φ200\Φ250\Φ300
(Inside Type) Φ200~Φ1500
Material 1Cr18Ni9Ti()

Vibration Accelarate
Speed Permitted
0.2g Piezoelectricity 0.2g
1.0g Capacitance 1.0g
Enclosure (General Type) IP65 (Submersible Type)IP68
EEX (ia)IICT 2~T5

Enviornmental Condition

Temperature
(Unexplosion – proof place)-40ºC~+55ºC
(Explosion – proof place) -20ºC~+55ºC

Ralative Humidity
≤90%

Atmospheric Pressure
86~106Kpa

Power Supply

Unexplosion proof Type
(Pulse output) +24VDC
(Current output) +24VDC 4~20mA

Explosion proof Type
(Pulse output) +24VDC +12VDCwith Zener-barrier LB978
LB978
(Current output)+24VDC 4~20mAwith Zener-barrier LB987S
LB987S

Output Singnals
2~3000HZ ≤1V ≥5V
Frequency pulse signal 2~3000 HZ Low eletric potential≤1V high eletric potential ≥5V
4~20mA≤300 Ω≤500Ω
2-wire type 4~20mA explosion-proof type load≤300 Ω unexplosion-proof type load≤500Ω
Flow Transducer Model Manual Memo
LU Vortex Shelding Flow Meters
G
B
Output Voltage Pulse Signals
4~20mA Output 4~20mA Current Signals
Transducer
Transmitter
B
E
Piezo Voltage Crystal Detect Element
Capacitance Detect Element
Detect Element
2
3
4
5
6
7
8
9
Flange Fasten Type
Simplified Inside Type
Ball Valve Inside Type
High Voltage Type
Submersible Type
Flange Replaceable Type
Flange Expandable Type
Flange Multifunction Type
() (Intelligent Intergration)

Connect Style
2
3
4
Liquid
Gas
Steam

Detect Medium

02
04
05
08
10
15
:
:
150
DN25
DN40
DN50
DN80
DN100
DN150
:
:
DN1500
(:mm)
Norminal Diameter(unit:mm)
B
P
Explosion-proof Type
General Type

Application Environment
1
2
3

4
Piezo Electricity pulse signals
4~20mA4~20mA Current signals
()
Display(battery self-supplied or Power external-supplied)
4~20mA+()
4~20mA+local Display (Power external-supplied)

Output Signals


LU

B E 2 4 10 P 2 :LUBE^2410^P2,,,100mm,,4~20mA.
Capacitance Vortex Shelding Flow Transducer,detecting steam,DN100, General Type, outputing current of 4~20mA.